NNPCNIPCO CNG Station

Inspect All CNG Cylinders Before Refill, SON DIrects Gas Refuelling Stations

The Standards Organisation of Nigeria has directed all gas refuelling stations to inspect all Compressed Natural Gas cylinders to ensure their suitability before they are refilled.

The directive followed reports from the unfortunate Compressed Natural Gas Cylinder explosion at the NIPCO CNG Refueling Station in Benin City, Edo State.

In a statement made available to NewsNGR, the Standards Organisation of Nigeria (SON) called on Nigerians to heed the warning against the use of substandard and uncertified CNG Gas cylinders.

It commiserated with those affected by the incident, adding that preliminary investigations have revealed the cylinder used to convert the vehicle differs and does not comply with the CNG Standards approved by the Organisation.

It said, โ€œThe Organisation has robust and effective regulatory measures in place to ensure that all CNG equipment and conversion kits conform to approved standards before being certified for public use.

โ€œThe conformity assessment schemes are designed to prevent the import, manufacturing, and use of substandard products.

โ€œIn addition, SON, in collaboration with the Presidential Initiatives on CNG and other relevant government bodies, is finalizing the Nigerian Gas Vehicle Monitoring System (NGVMS) โ€“ a platform that will provide centralized monitoring and surveillance of CNG systems to ensure that only vehicles equipped with certified conversion kits can access gas at retail outlets.

โ€œThe NGVMS will also offer a database of approved CNG equipment and suppliers which will go a long way in preventing the substandard installations and further mitigating the associated risks.

โ€œThis initiative reassures the public that CNG safety is a top priority and reaffirms SONโ€™S commitment to ensuring the safe use of CNG in Nigeria. It also urges all stakeholders to prioritize safety and recognize that LPG and other gas cylinders are not suitable for CNG containment.โ€

In the statement, SON highlight the structural differences between the LPG and the CNG Cylinders which are crucial to ensuring and maintaining safety under the high pressure associated with CNG Vehicles.

It added, โ€œThe LPG cylinders with a working pressure of 7 bar can withstand a test pressure of up to 30 bar of gas while the CNG cylinders are designed for much higher pressures with working pressure of up to 200 bar to withstand a test pressure of 300 bar and above.The LPG cylinders can have welded joints/seams while the CNG cylinders are seamless and do not have weld joints.

โ€œCNG vehicle users are strongly advised to install only SON-certified cylinders in their vehicles, as the use of uncertified cylinders presents serious safety risks which should not be overlooked.

โ€œFurthermore, SON charges all CNG refueling stations to undertake on-the-spot inspections to ascertain vehicles are equipped with approved conversion kits with required label identifying the conversion Centre.

โ€œThe Standards Organisation of Nigeria (SON) is unwavering in its commitment to the development of CNG productsโ€™ standards and their certification to meet safety requirements thereby enhancing safety in the CNG conversion process and strengthening the regulatory framework.โ€

...